INTERMEC SR61 MANUAL PDF

Everett, WA U. The information contained herein is provided solely for the purpose of allowing customers to operate and service Intermec-manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec Technologies Corporation. Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation Intermec Technologies Corporation. All rights reserved.

Author:Kilrajas Sarr
Country:Mozambique
Language:English (Spanish)
Genre:Career
Published (Last):16 June 2015
Pages:32
PDF File Size:8.21 Mb
ePub File Size:10.74 Mb
ISBN:917-3-93524-181-5
Downloads:8606
Price:Free* [*Free Regsitration Required]
Uploader:Gujar



Quick Links. User's Manual. Table of Contents. Page 2 Intermec Technologies Corporation. Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation.

All rights reserved. Page 6 Configuring the SR61 Parameters Page 7 Telepen Page 8 Accessories for the SR Disclaimer of warranties: The sample code included in this document is presented for reference only. To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor.

Visit the Intermec support services knowledge base Knowledge Central at information or to request technical support for your Intermec product. Telephone Support These services are available from Intermec. Before you work with the SR61, you should be familiar with your network and general networking terms, such as IP address.

You should also be familiar with Bluetooth communications. Page Patent Information 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,,; 6,, There may be other U.

In this illustration, the scan engine option is V or 1D linear imager. Page Checking The Battery Status Note: If you have a near-far range imager, it may take up to 3 seconds for the status light to turn on after you pull the trigger. If the status light on the SR61 turns red when you try to turn on the scanner, you need to charge the battery. Page Understanding The Lights The lights on the SR61 indicate the status of the battery, a successful decode of a bar code, or the status of the Bluetooth connection.

Status Light Description Page Understanding The Beeps The SR61 is trying to establish a Bluetooth connection with the host computer, or the SR61 is moving out of range of the host computer. A Bluetooth connection to the host computer is not established. Once you find the misplaced SR61, pull the trigger to stop the beeps.

Page Scanning Bar Codes Long-term exposure to the laser beam can damage your vision. The type of scan engine you are using and the type of bar code you are decoding determines the way you scan the bar code.

Page 21 To scan a bar code label with a laser scanner or 1D linear imager 1 Point the SR61 at the bar code label and hold the SR61 at a slight angle 15 to 25 cm 6 to 10 in from the label. Page Using Vibrate Alert The aiming beam is smaller when the imager is closer to the bar code and larger when it is further away. When the SR61 successfully reads a bar code label, the SR61 creates a single high beep and the status light briefly turns green. To connect to a host device, you may need to install EasySet, the Intermec configuration application that allows you to change settings on the SR When the SR61 connects to your Intermec computer, the SR61 emits a series of beeps from low to high, and the blue Intermec Ready-to-Work indicator turns on and stays on.

The SR61 is ready to scan data. Connecting as a keyboard wedge lets your host PC receive data from the SR61 as it would from a keyboard. The data is entered into your application.

These characteristics are controlled by configuration commands. The values you set for these configuration commands determine how the scanner operates. This configurations are indicated with blue text. The SR61 is updated with the new configuration command settings.

SPP allows your SR61 to use the Bluetooth link as a serial port to communicate with your host device. You can send information from the SR61 to your serial application without having to modify your application. For enhanced security, you should configure your SR61 for limited discoverability, which allows the SR61 to be discoverable by Bluetooth management applications for only 30 seconds.

Charge the battery immediately, and then try scanning again. The SR61 is trying to establish a Bluetooth connection with the host computer, or the SR61 is moving out of range of the host computer. Page 40 SR61 is waiting.

Make sure the blue Intermec Ready-to-Work indicator is on and the SR61 is connected to your host device. When you reset your SR61, the scanner control firmware is restarted. Page 43 Click the link to download the SR61 firmware upgrade d Unzip the. To clean the scanner window, you can use soapy water, a solution of ammonia and water, or isopropyl alcohol. Page Configuration Command Reference Use this chapter to learn about the configuration commands supported on the SR Then, scan the bar codes onscreen with your SR61, or print the setup sheet and scan the bar codes.

Page Sr61 Configuration Commands By default, the SR61 aimer beam flashes repeatedly while the imager attempts to read a bar code. The aimer beam flashes on so that you can see where to aim the SR61 and flashes off to read the bar code with the least amount of interference from the light of the aimer beam.

To connect to a host computer, enter the Bluetooth address of the computer and scan the bar code with the SR To disconnect, scan the disconnect bar code. When your SR61 is discoverable, it is visible to other Bluetooth devices in communication range. Bluetooth Discoverable States State Fully In this way, FNC2 can be used to concatenate several symbols before the data is transmitted.

Error Beep Enables or disables the error beep. Your SR61 emits an error beep without affecting the configuration of your SR61, when you scan a configuration bar code that is damaged or unknown. You can set Good Read Beep Duration to a value from 0 off to ms.

The symbols are concatenated as they are scanned and can be scanned in any order. Page Planet Sets the preamble that precedes any data you scan. Common preambles include a data location number or an operator number. When you select a lower decode security level, the SR61 can decode bar codes with poorer print quality. When you successfully scan a configuration bar code, you hear the setup beep, and the configuration of the SR61 is changed. Enables or disables the crackle sound when you scan a stacked 2D bar code.

Page Telepen There can be other data fields after the Serial Number, usually either AppIDs or DataIDs, which are governed by whether or not there are alpha characters in the serial number. Country Of Origin is another typical data field included in this symbology. The scanner beam blinks while the SR61 is waiting to transmit data.

During this time, you can scan configuration bar codes but not data bar codes. Page Trigger Timeout near-far range area imager only. Sets the trigger timeout for the Trigger Mode command. You can set trigger timeout from 1 to seconds. Trigger Mode Level Page Gtin Processing laser scanner only.

Causes the SR61 to perform a restart and restores all configuration commands to their default settings, only if no settings are locked. To order accessories, contact your local Intermec sales representative.

Page 85 Interleaved 2 of 5 command, Interlink firmware upgrade application, described, Intermec computers connecting to, supported, using to configure the SR61, contact information, Ready-to-Work indicator described, illustration, SmartWedge, described, telephone support, ISBT command, Japan Post command, Print page 1 Print document 90 pages.

Cancel Delete. Sign In OR. Don't have an account? Sign up! Restore password. Upload from disk. Upload from URL.

AIA DOCUMENT G706A PDF

Intermec SR61 User Guide

Quick Links. Download this manual. SR 61B. Table of Contents.

ZAATAR W ZEIT MENU PDF

Intermec SR61 SR61BV0400 Leaflet

.

AM2302 DATASHEET PDF

Intermec SR61 User Manual

.

EDAN M80 PATIENT MONITOR PDF

User s Manual. SR61 Cordless Scanner

.

Related Articles